Run the Notification LED Test Suite by executing the command line s tux -o -d nledtest in a command window.

The Notification LED Test Suite can have one or more optional command line parameters to modify test behavior. To specify command line options, use the -c command line option for Tux. For more information about command line parameters for Tux.exe, see Tux Command-Line Parameters.

The following table shows the command line parameters for the Notification LED Driver Test.

Command line parameter Description

-?

Displays all command line options and descriptions

-i

Runs in interactive mode; default is to run in non-interactive mode.

This parameter affects test cases 3001-3003 and 4100-4103.

-n n

Specifies the minimum number of NLEDs required; default is 0.

This parameter affects test case 3001.

-v

Vibrator required; default is no vibrator required.

This parameter affects test case 3002.